Home / Articles / Hayward Aqua Rite Error Code Guide

Hayward Aqua Rite Error Code Guide

In my professional and personal experience, I have come to the conclusion that hardly anyone keeps owner’s manuals around. Don’t worry, this isn’t a dig at you but for some reason no one ever thinks he/she will need it again. Why? I am not certain. It is safe to say that somewhere down the line, the product will fail. And once it fails, the owner’s manual should be one of your first go-to documents for resources.

Sometimes, it’s not about the initial need for the manual, but for issues that spring up down the line. Pool owners are a group of consumers who I think need to keep all their manuals around, especially if you own any type of automation or salt chlorine system. The cool thing about salt systems is that when an error occurs, it typically gives you an error warning or code. That code gives customers a better idea of what the problem is and how to address the issue. But where are those codes and explanations usually? Take a wild guess.

The owner’s manual.

Hayward’s AquaRite Salt Chlorine Generator is one of the most popular lines on the market today. It is one of the easiest ways for you to sanitize your pool. Although I won’t get into too many details on how great the product is, you can read our customer reviews to get unfiltered opinions about it.

Still, one thing I do commend Hayward for is their simplistic error code guide. Compared to a lot of others on the market, going through their manual and troubleshooting guide was as customer friendly as you are going to get. But what good is a manual if customers don’t keep it?

Hayward Aqua Rite

Capture41The Hayward AquaRite system was strategic in the design in the sense that there aren’t too many variations of error codes programmed into their system. Unlike the Jandy AquaPure unit, which displays a number that then corresponds to a particular error, the Hayward Aqua Rite is simplistic in nature. It tells you the source of the issue.

If you take a look at the picture on the left, there are only 4 different error functions: No Flow, Check Salt, High Salt, and Inspect Cell. Although there may be several reasons for the error code to appear, having only 4 possibilities is great odds for a pool owner. It also makes it very clear to the pool owner what the issue might be once they venture out to the system. Let’s explore the different Hayward Aqua Rite error codes, what they mean, and how you can get rid of them.

Check Salt & Inspect Cell

Seeing as this is a salt chlorine generator, one of the most frequent error codes you will see will have to do with your salt checksaltlevels or the cell where the salt is produced. And because one directly affects the other, both lights will appear when there is an error concerning the salt levels.  Let’s dig a little deeper.

I. ‘Check Salt’ Light & ‘Inspect Cell’ Light Flash Together

When both these lights flash together, it means your salt level is between 2500 ppm and2600 ppm. At this moment chlorine is still being produced, however your salt levels are dwindling. Keep in mind, your ideal salt level should read 3200 ppm. Your AquaRite system may be working efficiently and your pool may be clear at the moment, but in a week or so, it may not be the case anymore.

Remedies:

  1. Independently verify the salt levels in your swimming pool. You can utilize one of our at home testing kits, or you can get your water tested at your local pool store.
  2. Once your water has been tested, add salt to your pool to bring your levels back to the recommended 3200 ppm. You can review how to add salt on our site, as well.
  3. Inspect and clean cell if, necessary.

II. ‘Check Salt’ Light & ‘Insect Cell’ Light Stays On

If both the Check Salt and the Inspect Cell light stays on that means no chlorine is being produced at this time. That is a big “uh-oh” for any pool owner. It also means your salt level fell below 2300 ppm. Yikes! Both lights will also stay on if the control is set to the wrong turbo cell type, or if the cell is unplugged.

Remedies: 

  1. Independently verify the salt levels in your swimming pool. You can utilize one of our at home testing kits, or you can get your water tested at your local pool store.
  2. Once your water has been tested, add salt to your pool to bring your levels back to the recommended 3200 ppm. You can review how to add salt on our site. If your independent testing shows your salt levels are correct, but your system is showing something different, you may need to recalibrate your Aqua Rite unit.
  3. Inspect and clean cell, if necessary.
  4. Verify if the control is set to the correct turbo cell.

III. Only ‘Inspect Cell’ Light Flashes

If the ‘Inspect Cell’ light flashes by itself, it is an early indication that the cell life is coming to an end. Each cell is equipped with 500 operational hours and requires a manual reset once it expires.

Remedies

  1. To reset the cell, hold down the ‘Diagnostic’ button for 3-5 seconds.

High Salt

The ‘High Salt’ light is exactly what it says There is literally a higher recommended amount of salt in your pool. Your unit will detect and alert this to the owner.

highsaltI. ‘High Salt’ Light Stays On

The ‘High Salt’ light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or you simply have too much salt in your pool. The LCD display will read “HI”.

Remedies

  1. Independently verify the salt levels in your swimming pool. You can utilize one of our at home testing kits, or you can get your water tested at your local pool store.
  2. Once your water has been tested and the reading is too high, reduce the levels of salt in your pool to bring your levels back to the recommended 3200 ppm.
  3. Verify if the control is set to the correct turbo cell.
  4. Verify cell amperage to ensure it is not above the maximum limit for your model. Check below for the maximum current amps before the unit shuts down.

005

No Flow

The ‘No Flow’ light is an indication that there is something funny going on with the flow in your piping or the flow switch itself. If there is an issue with the flow, the ‘No Flow’ light will flash up to 60 seconds at start up. If none of the below remedies solves your issue, you may need to replace your flow switch.

Remedies

  1. If a LED is flashing, wait 60 seconds after starting the filter pump. Check for possible disruption inside of the flow T. yupInstallation requires 12 inches of straight pipe before the flow switch. There should be no elbow after the flow switch.
  2. If a LED is ON, check to see if the flow switch was installed correctly. The arrows at the top of the hex nut should point in the direction of the water flow. (Your flow switch requires a minimum flow rate of 11 GPMs  to stay consistently closed.
  3. Check the flow switch for damaged or cut wires.

Low/High Cell Temperature

Although there isn’t an error setting for temperature on the control, the LCD monitor will let you know if your water is either too hot or too cold for standard operation. The cell’s operating temperature range for the cell is 50F to 140F. The output is scaled back to 20% at 60F and output completely stops at 50F.

The LCD display will read COLD when the water temperature is below 50F.

The LCD display will read HOT when the water temperature is above 140F.

No manual is more efficient than the technical support provided by the manufacturer. The manual allows you to get familiar with your system and put your DIY skills to the test. If at any point you do not feel comfortable or simply just don’t know what to do, definitely give us a call. If it’s something that we can’t solve, we will put you in contact with a rep from Hayward.

Feel free to check out our how- to guide section for many more how-to guides dealing with the Hayward Aqua Rite system.

author avatar
Charlie Ramirez
Writer at InyoPools.com, brings a wealth of knowledge and expertise in pool care and equipment, helping pool owners make informed decisions for over a decade.

Related Videos

127 responses to “Hayward Aqua Rite Error Code Guide”

  1. MATT LANTIERE Avatar

    I had some issues with this Aquarite system .. lead me to replacing both the display and the main board — now each morning it reads “700” on the display, as well as “CHECK SALT” and “INSPECT CELL” stays on (stated in earlier question that it blinks — but actually stays on) … go through the calibration routine and everything seems to go back to normal — until the next morning. (kind of like GROUNDHOG DAY) — what’s you thought?

    1. Matthew Simmons Avatar

      Matt, It’s possible that the wrong cell size is selected in the diagnostics. It could also be the cell needs to be cleaned or replaced.

      which TCELL are you using, and have you made sure the control is set for it? How to Read and Adjust the Hayward Aqua Rite SCG Operational Values

  2.  Avatar

    what are error codes 88-1 and R 8.1? Thanks

    1. Matthew Simmons Avatar

      The R 8.1 is likely the revision ID for the main pcb. The 88-1 is not listed in any guides. The only Aquarite value that matches that format is the “Program Code” but it should read AL-0

      1. Sunny Avatar

        88-1 is generator model number and r8.1 is the the version, they should change and are not error codes.

        1. Matthew Simmons Avatar

          Ok, so this guide and these comments are for the Hayward AquaRite, specifically. I am not familiar with the Intex brand, but you should be able to find a manual through Google.

  3. Mike Avatar

    *The power/generating indicators are not illuminated at all.

    1. Matthew Simmons Avatar

      First, I would make sure it is wired correctly and that the unit is getting the correct voltage. If the circuitry checks out, I would do the following checks, I pulled from our article: Troubleshooting Your Hayward Aqua Rite System

      The NO FLOW LED stays ON when there is a flow switch problem.
      – Verify if your flow switch was installed correctly.
      – The arrow at the top of the hex nut points in the direction of the water flow.
      – Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed
      – Check for damaged or cut wires

      Possible Remedies
      Step 1: With your pump running, double-check the positions of your valves.

      Step 2: Did you properly install your switch? The arrow should point in the same direction as the water flow. If it is not, re-align your flow switch.

      Step 3: Double check the wires on the flow switch for damage. If you see any damage, replace your flow switch. If there isn’t any apparent damage, keep reading.

      Step 4: Verify your pump’s pressure. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow.

      Step 5: Replace your switch.

  4. Mike Avatar

    I was getting a solid no flow indiciator light, so I have replaced the main Pcb board. The display doesn’t turn on when the power is on, but it turns on briefly whenever the power is switched off. I replaced the display and the same problem occurs. When I quickly switch the power on-off-on, the display finally turns on and the no flow indiciator is still illuminated. I’m $400 in the hole and it still without a solution.

  5. Rich M Avatar

    I have a older(2001) Aqua Rite chlorine generator with Tcell-15. I have repaired the thermister several times over the years and replaced the LCD display board a few years ago. A new cell a few years ago too. It has been running fine, until a recent problem.

    We were away and the pool water level dropped below the input line and skimmer. The pump and generator were on during this time, over a weeks time(on daily for 6 hours), with now flow to and from the pool. I have not refilled the pool as it appears there is a major leak and I will have a pool service check that. The pump runs with whatever water is in the filter. I am not sure if the pump impeller is damaged yet but I do not hear anything broken.

    However, when I turn on the pump/generator power, I expected only the “No Flow” lamp to be lit. But….the generator front panel has ALL lights on solid (not blinking), and the LCD display is blank.

    Did the condition of no pump flow for several day-cycles somehow destroy the Aqua Rite generator?

    1. Rich M Avatar

      This is a self-reply for others in the future…..

      Problem solved! I unplugged the cell cable, reconnected it, and the generator is now working properly. It must have had a bad connection. I shut the control valve to the skimmer/side inlet so it only draws from the bottom of the pool. The generator came on normally after the No Flow delay and is generating chlorine now.

  6. Michelle Avatar

    I have had an error code all summer but I can’t find out anywhere what it means. It says “HOE” but it’s not the whole E, it is missing the top horizontal lines of the E. It says no flow, and the generating button flashes. Does that make sense? We cleaned the cell. When i called the pool store she said everyone is having trouble this summer because it was so hot, and the temperature was up to 90 at one point, but now it is down below 80, and there is still the same error message. Thanks.

    1. Matthew Simmons Avatar

      The board is spelling “HOt” to denote the water temperature is reading above 140 degrees Fahrenheit. More than likely, this temperature reading is not correct. To determine if you need to replace the cell, check the water temp on your Aquarite’s control panel diagnostic’s. If the water temperature reads 215 degrees F, the cell temperature sensor is shorted and the cell needs to be replaced.

  7. Joyce Avatar

    I have a customer that has a code on their salt generator the code is Pcb. what does that mean.

    1. Matthew Simmons Avatar

      Usually, an Aquarite PCB error code can be fixed by soldering in a new current limiter. If that doesn’t work then you would need to replace the AquaRite Main PCB (OEM) – GLX-PCB-RITE

  8. Jan Vacha Avatar

    We have a newer Hayward salt cell! Had to replace the stage flow sensor switch- now it reads the water temp at 208 degrees ? It’s 89. Salt cell didn’t produce chlorine- what’s up?

    1. Matthew Simmons Avatar

      You may want to try to recalibrate/troubleshoot the unit; also make sure the correct cell type is selected in the settings. If this unit is new, you may also want to try contacting the manufacturer to determine if the unit is defective.

  9. Allen Finn Avatar

    System is not working. All four lights on panel are lit. No flow, check salt, high salt, inspect cell. Display reads. PCB. And at one point it showed 700. Do we need the display board or the control board.??

  10. Pat Avatar

    What does it mean if the checks salt light is flashing but not the inspect cell?

    1. Matthew Simmons Avatar

      Check the salt levels.

Leave a Reply