Home / Articles / How to Troubleshoot Pool Pump Run & Start Capacitors

How to Troubleshoot Pool Pump Run & Start Capacitors

Knowing how to test a pool pump capacitor can save you time and money when the pump motor fails. Every day that a pump is down, the likelihood of a lengthy and expensive cleanup increases. Troubleshooting a pump motor should begin with testing the capacitor(s).

What Is a Capacitor?

The basic definition of a capacitor is a device that’s used to store an electric charge. Most pool pump motors utilize a start capacitor and/or a run capacitor. They both look similar to a large battery. Start capacitors are usually located at the back of the motor and the run capacitor is located at the top of the motor.

How To Test A Pool Pump Capacitor

Symptoms of a Bad Capacitor

Humming. Is your pool pump motor humming, but not turning on? Most pool motors require extra torque to get the motor up to speed. A failed capacitor will prevent the motor from turning over. Another cause of humming could be a seized motor shaft. If you can spin the motor shaft manually, the capacitor is likely the cause of the humming. If the shaft does not spin manually, the bearings or complete motor should be replaced.

Overheating. It is common for pool motors to run on the hot side. However, the motor will shut itself down if it is running too hot. A defective run capacitor can cause the motor to run at a higher amperage. Higher amps mean more wattage and more wattage means more heat. Other symptoms of a pool motor overheating would be an oversized impeller, bad windings or high voltage.

One Speed Working on a Two-speed Motor. There are a couple reasons why a two-speed pool pump motor would only run on high or low speed. As you can probably guess, the run capacitor is a frequent offender. If it’s not the capacitor, it’s likely a bad phase winding and the motor needs to be replaced.

Testing the Capacitor with a Multimeter

  1. Remove the cover at the back of the motor or on top of the motor to expose the capacitor.How To Test A Pool Pump Capacitor
  2. The capacitor will store an electrical charge. It will need to be shorted out by placing an insulated screwdriver across the leads of the capacitor. CAUTION: Capacitors have been known to explode when shorted out. For this reason, wear eye protection and place a cloth over the capacitor before shorting it out.
  3. Remove the leads to the pool pump capacitor. Note the placement of the leads so that you can restore them to their correct positions when you reconnect them.
  4. Set the multimeter on ohms to 1K.
  5. Slip a heavy piece of paper between the points on the switch.
  6. Attach one probe to each terminal. On an analog meter the needle should move rapidly to right then slowly drift to the left. If a digital meter is used, readings should start low and rapidly increase to maximum value. If the needle or number starts at zero and doesn’t move, the capacitor is bad and  therefore needs to be replaced.

Replacement

Replacement capacitors must have the same MFD or UF rating as the original. If the same voltage rating is not available, it is acceptable to use the next higher voltage. For example, if a 370 volt unit is not available, use the next rating which is a 440 volt.

Other Related Content

How to Replace a Pool Pump Capacitor

author avatar
Rob McLintock Ecommerce Director
With over 17 years at InyoPools.com and more than two decades in the pool industry, Rob is a seasoned expert dedicated to helping pool owners succeed. As one of Inyo’s original content creators, he specializes in troubleshooting, sizing, and identifying pool equipment of all kinds.

Related Videos

61 responses to “How to Troubleshoot Pool Pump Run & Start Capacitors”

  1. Travis Avatar

    Woke up this morning and pool pump was not running. I have power to both the timing box and pump itself. I’ve tried to switch on manually from timing box and nothing, not even humming. Also I can turn the motor shaft freely by hand. Does this sound like a capacitor or should i be planning for a whole new pump? Current pump is a Pentair 1.0 model number/part number SF – N1 – 1A / 340038

    1. Matthew Simmons Avatar

      Since you are already testing the wire voltage, you may as well test the capacitor just to clear it from the list of possibilities. If the capacitor or the motor is the only issue, the housing is still in good working order, then all you need to do is replace the failed part.

  2. Whitney Avatar

    Hi! About a year ago my Polaris booster pump stopped working. All it would do was make a horribly loud humming/buzzing noise – and I’m just getting around to it (I know, I know). I watched one of your videos about capacitors yesterday which inspired me to think that I might be able to fix it on my own. I looked last night and found the following information:
    PB4 Booster Pump – Enclosure Type 3
    Century Pool & Spa Motor 1081 Pool Pump Duty
    Serial 056103M
    Part 7-173840-23
    HP 3/4 SF 1.5
    HZ 60 RPM 3450
    Volts 230/115

    My question is this – I didn’t take the capacitor cover off last night because it was almost dark. Do I have to take this off to get the information that I need to order the correct capacitor to try or is the information that I gave above enough to know which to order? Also, I haven’t tried to turn the pump on in at least 6 months since it stopped working. The hum is not as loud now as it was then. Does this mean that now there’s something else wrong?

  3. steve robinson Avatar

    How long should a capacitor last, mine are only lasting a few months?

    1. Matthew Simmons Avatar

      I don’t know the exact expected lifespan of a capacitor, but it is definitely longer than a few months. if you are replacing them that often, you have something causing them to fail. We list the common causes and how to fix them in this guide: PSC Ep. 86: Why is my pool pump motor capacitor failing?

  4. Andy Avatar

    I have a Sta-Rite Dyna-Pro-E Pump (2-Speed) #MPEA6YG-207L that will only run on low speed. It will sometimes run at high speed if I flip from low to high while it is already running but then it shuts down a short time later (overheating?). It will not start on high speed. The motor is #AE100GLL-Y. What capacitors would this take?

    1. Matthew Simmons Avatar

      This guide gives you a few other things to check: My Pool Pump Runs On Low Speed But Not On High Speed. The AE100GLL-Y uses a start capacitor 2509516-002 and a run capacitor (628318-309)

  5. John Boughton Avatar

    YOU GUYS ARE KILLIN ME ! SO MUCH BAD ADVICE HERE! I’M A TECH AND THERE ARE GAPS IN MANY OF THESE COMMENTS . ALL OF YPU SHPULD BE CALLING A MOTOR TECHNICIAN. NOT AN ELECTRICIAN OR POOL GUY BUT A TECH. ONLY FOUND USUALLYIN HVAC OR MOTOR REPAIR INDUSTRY.

    1. Matthew Simmons Avatar

      Spoken like a true unbiased professional.

  6. Russ Avatar

    Hello. I have a Hayward pump sp32152ee. Which start and run capacitors do I need? 1.5 hp dual speed. Thx

    1. Matthew Simmons Avatar

      The run capacitor is the 628318-307 and the start capacitor is PTMJ189

  7. Charlie Avatar

    pump was shut off this morning tripped circuit breaker Pump model Pentair 1.0 HP whisperflo WFE4
    ran for a second then tripped again
    Now once you reset it it trips immediate
    checked pump motor shaft spins fine not frozen
    Think it is the capacitor ?

  8. Rob Avatar

    Rob take a look at the dropbox URL – I posted a pic of the capacitor. Do you sell this?

    The pump is the 3/4 HP (using it for solar)
    Specs ono cap: 15uf 370V

    1. Rob McLintock Avatar

      The picture you posted is the run capacitor. The run capacitor is part number 5270-01. There should also be a start capacitor at the back of the motor. You’d have to remove the end cap to see the start capacitor.

      1. Rob Avatar

        Ahhh I didnt realize there are two caps. I’ll look at the start cap. Thanks for your attention.

  9. Rob Avatar

    Thanks for the quick reply! I’ll take a look at the Cap but I believe the motor is 230v. From reading it sure seems like the capacitor is a common issue on pool pumps 🙂

    Video and pics of pump https://www.dropbox.com/sh/mwrt559rjr6bx77/AAAIVfUqITO6I82HeKojQjEya?dl=0

    1. Rob McLintock Avatar

      The capacitor voltage can be different from the motor voltage. It doesn’t always match. You can have a low voltage capacitor and a high voltage motor.

  10. Rob Avatar

    Hello my Pentair Sta-Rite P6E6D-205L doesn’t start. When turned on it hums for 7-8 seconds, then a single relay click sound comes from the motor and it stops humming. If I leave it alone in the on position it repeats this every 5-10 minutes. What do you think I’m dealing with?

    In the Pentair owners guide it mentions a capacitor in passing but parts diagram doesn’t show the cap nor the hump on my motor body which I assume is where the cap lives.

    1. Rob McLintock Avatar

      Hello Rob – It sounds like a bad start capacitor. The start capacitor is usually located at the back of the motor. The replacement start capacitor for the P6E6D-205L should be part number 5270-11. The MFD/UF rating is 124-149 and the voltage is 110-125. You can verify the specifications by looking at the start capacitor on your motor.