Home / Articles / The Most Common Swimming Pool Heater Problems

The Most Common Swimming Pool Heater Problems

Installing and troubleshooting a heater that is still under warranty without proper licensing can forfeit your warranty under the manufacturer’s terms and conditions. If your heater is out of warranty, sometimes, it’s simply cheaper to do it yourself. If you yourself in this scenario, this blog article is for you. In this blog article, we cover the most common swimming pool heater problems a pool owner might encounter and remedies to fix the issue.

My Heater Won’t Ignite

One of the most common problems with pool heaters is it failing to ignite.

Is your heater turned ON and the temperature set correctly?

  • Ensure that the thermostat is set to a higher temperature than the current water temperature.

Is your pump running with a clean filter and basket?

  • Inspect the pump and filter and clean if necessary.

Make sure that the pilot is lit (millivolt heaters).

  • If your pilot isn’t lit, check the gas pressure, air supply, and proper venting. Make sure the pilot tube is intact and not clogged. For MV heaters, if the pilot won’t stay lit, check the output on the thermocouple.

Is the gas supply valve in the ON position?

  • Without gas, the heater won’t operate. If the supply valve is OFF, turn it ON.

Are the plumbing and filter valves open?

  • Make sure to keep your valves open as to not prevent the water flow.

Low Water Flow

In order for a heater to operate smoothly and efficiently, it’s important that pool system maintains a consistent flow of water. Manufacturers equip swimming pool heaters with pressure sensors. These special sensors monitor and detect changes in water flow. For example, in some cases, you will see a “Low Water Flow” warning pop up on your heater’s LCD screen. Or, you might notice your heater isn’t pushing out as much warm water as it should or used to. Honestly, this is a very common occurrence. If you are experiencing low water flow, or your heater won’t start, ask yourself the following questions:

Have you cleaned your filter lately?

  • Monitor your PSI reading on your filter’s pressure gauge. If the PSI is too high, clean your filter.
  • Increasing pressure goes hand in hand with the decrease of water flow.

Is your pump basket dirty?

  • Check your pump’s strainer basket. Remove the basket and remove the debris with a hose.
  • Ensure the pump basket and lid are in good conditions. No cracks.

Do you have too many water features operating at once?

  • Your pool pump only moves a certain number of GPMs, therefore, too many water features can dramatically decrease your water flow.
  • If possible, replace the motor with a larger one.
  • Close water features, or alternate them, until the pool heats to the desired temperature.

Defective Pressure Sensor/switch (Most Common)

  • The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on.
  • The pool pump must be ON and your filter clean for the switch to close and allow voltage to pass through.
  • Test the voltage reading on the pressure switch with a multimeter.
  • Replace the pressure switch if necessary

Are you using the low settings on your variable speed pump?

  • For operation, heaters require a minimum GPM flow. If you are running your variable speed pump on the low setting, make sure you meet the minimum GPMs for your heater.

Pool Heater Turns ON and OFF (Cycles)

If your swimming pool heater is cycling ON and OFF, it is an early indication that the electrical connection or power supply is experiencing issues. However, it isn’t ALWAYS the case. There are other factors that can actively contribute to your heater’s ON and OFF cycles.

Is your pool water chemistry consistently and accurately balanced?

  • Poor water chemistry is one of the leading causes of equipment failure, especially pool heaters.
  • Test your water before adjusting your chemical levels. If unsure, please refer to the heater’s manual for the recommended chemical levels.

Have you inspected the pressure sensor, thermal regulator, and/or the high limit switch?

  • Inspect these parts for corrosion, scaling, and/or any electrolysis issues.
  • If the pressure sensor, thermal regulator, or high limit switch is faulty, corroded, or defective- replace it.

Have you cleaned your filter?

  • A dirty filter can cause low pressure and as a result, cause the heater’s pressure switch to turn OFF. A dirty filter can prevent a heater from firing and it can also cause your heater to shut off before warming the water to the desired temperature.

When’s the last time you have inspected and cleaned the heat exchanger?

  • Deterioration of the heat exchanger can impact your heater’s operation. Inspect your heat exchanger for chemical or sanitizer damage.

Pool Heater Isn’t Heating

Sometimes, your pool heater ignites but doesn’t reach the desired temperature. Or, maybe your heater isn’t generating heat at all. Both situations are very common.

Inspect your temperature sensor.

  • Make sure you have installed the temperature sensor correctly and it is in good condition.

Double check your thermostat settings

  • Set your thermostat to a higher temperature.

Did you properly size your pool heater?

  • If your heater is undersized, it will have problems heating your pool up. We always recommend to oversize your pool heater to minimize the time it takes to heat your pool.

author avatar
Charlie Ramirez
Writer at InyoPools.com, brings a wealth of knowledge and expertise in pool care and equipment, helping pool owners make informed decisions for over a decade.

Related Videos

209 responses to “The Most Common Swimming Pool Heater Problems”

  1. Amy L. Cart Avatar

    Pentair Master Temp 400. No service system or service heater lights. No codes lit on back of the board. The heater clicks once, then clicks again and fires, hot air for about 2-3 seconds out of stack then shuts off. Attempts to fire again. Same thing. Water flow is fine. Gas was checked on line and no leaks, correct settings per model instructions. What should I be looking for?

    1. Paul Abrilla Avatar

      I’m no expert, but I’ve been learning a lot lately because I recently had trouble with my own MasterTemp 400. Check the Thermal regulator. There’s a lot of videos out there about it. It’ll te you how to check and replace. Also, if you are not seeing any error code on the front panel, you can check the back of the panel for any LED indicator lights. There are also videos about this.

      1. Matthew Simmons Avatar

        This is my go-to heat pump model. For a pool your size, you will need a higher BTU size. Raypak Classic Series Heat Pump 140,000 BTU – 016033

    2. Matthew Simmons Avatar

      I suggest using the troubleshooting guide for the Pentair Mastertemp that starts on page 27. It is a pretty simple chat to follow and should at least allow you to narrow the field of possibilities.

  2. Jade Avatar

    I have a Raypak RP2100 heater. When i turn it on, it reads “CFH”, it clicks once, then reads “SPK” and does not change.

    1. Matthew Simmons Avatar

      Is the pilot lighting? If so, then the proving signal is not getting back to the PC Board. Confirm that all gas valve wiring is intact and connections are solid. Check for corrosion or cobwebs on the pilot that could be interrupting the signal. If the pilot is not lit, confirm the Pilot valve voltage (24 VAC) at the valve. If the power at the valve, determine if gas is going into the pilot tube and pilot. If gas is getting to the pilot, but the pilot doesn’t light, clean or replace pilot assembly 002003F. If there is no gas coming from the energized pilot valve, replace valve. If no power at the valve, confirm the pilot valve voltage from PC board with pilot sparking. If no power, replace the board. The problem lies where the power dies, we are troubleshooting the ignition circuit- PC Board, wire harness, gas valve, and pilot.

      Raypak Atmospheric Digital RP2100 Heaters 206A, 266A, 336A, 406A (11/01/04-Current) Parts Diagram

  3. Colin Peeples Avatar

    I have a MasterTemp 200. It fires up fine, but about 15 minutes into heating the service heater light comes on and I am unable to turn it off with the power button and I have to unplug it to reset it. It fires up fine again then the same thing happens. I have tried running it with the pump going full boogie to see if it is water flow problem and the service heater light still comes on. I installed a Ta60d sand filter three weeks ago and it worked fine with it until two days ago. Advice?

    1. Matthew Simmons Avatar

      Have you tried cleaning the filter to see if that fixes any flow issues?

      This is an excerpt from the MasterTemp troubleshooting guide

      mastertemp 200 troubleshooting guide

  4. John Avatar

    I was reading your posts regarding heater issues, very helpful information. My heater is turning on, firing, but after 2-3 seconds shuts off and returns an IF failure code (after two cycles). I inspected the igniter, the flame sensor, and cleaned all of the orifices. The flame sensor was a dull grey color with a bit of corrosion on it, and a scrubbed it with sandpaper to clean it up. The igniter has a bit of carbon build up but came off with my finger. Orifices were clean.
    I suspect maybe it’s the flame sensor? Any other suggestions?
    I had a pool guy out to look at it due to this issue a month ago. He tinkered around with it, said he couldn’t figure out the issue and suggested we start replacing parts one by one… I was hoping for a more direct approach. Then when he left the heater started working! So it’s been a month or more that it was running.

    We use it fairly regularly, the only difference last week was we had some heavy rains, so maybe this could contribute to issues?

    1. Matthew Simmons Avatar

      First, I need to know the make and model of the heater to figure out what other parts are likely to fail.

    2. Skiingmadman Avatar

      yes, my sprinklers hit the top of the hayward panel, putting some water in the exhaust and my heater won’t work for a day or two until it drys out..

    3. Paul Avatar

      John, I am having the same problem. Did you ever get this resolved? If so, what did you do?

  5. Robin Stielow Avatar

    Matthew hasn’t been heard from since just after Tax Day. What happened to him??

  6. Kendra Avatar

    I have a Pentair mini max 100 heater hooked up to a cedar hot tub. The heater only comes on if it’s turned all the way up. I would appreciate any information to fix this problem.

  7. Kevin R. Avatar

    I have a Pentair Master Temp 300 Pool Heater that is 6 years old. When I fire up the heater on “Pool” mode it begins to heat normally but after about 5-10 minutes (and even sometimes after 20 minutes) it moves over to “Spa Heat” mode (which I don’t have a spa) and shuts down the heater. No code is present. I have replaced the Stack sensor thinking that it was the problem. Any ideas on what the problem could be?

    1. Matthew Simmons Avatar

      Is the heater hooked up to an automated control or is it standalone?

  8. Konrad Avatar

    I have a H200 gas heater. It will turn on and turn back off after about 45 seconds. When it turns off it also turns the pilot flame off. it will kick back on when I get the pilot lit again but turns off again. Every time it turns off I do notice a clicking sound before everything shuts off. Any ideas?

    1. Matthew Simmons Avatar

      What is the full model number? 3-5 different H200 models have varying firing processes.

  9. Phil Avatar

    Hi, got a Hayward HP75TR, ’bout 3 years old now. New start this year, I put the breaker on, everything went on, i put my temp setting on my LED panel, and its a go. 2 hours later got a Error Code E08. Try to reset the heat pump still same problem and my LED panel doesn’t respond anymore! Might be a connection problem!! Is this is a common problem?? do i have to change my LED panel or the board itself inside?? Thank You!

    1. Matthew Simmons Avatar

      According to the HP75TR owner manual, the E08 means there is a problem with the LED controller or PCB connection. You need to check the connection of the NET and NET 1 cables. Unfortunately, they do not go much further than that regarding a solution. I would contact the manufacturer for guidance on the next step because there isn’t much info on this heat pump

  10. Don Avatar

    Hi,I have a Raypak 266 heater about 7 years old, everything is running fine. the pool place thinks it might be putting copper into my pool. Do I have to take it apart to check the heat exchanger ? how can I tell if its bad ? no leaking going on at all. Thanks a bunch