What are the Electricity Requirements for Above Ground Pools?

What are the eletrical requirements for installing above ground pools?

This may not sound possible, but way back in the eighties I built an above ground swimming pool at a home that didn’t have electricity. I remember it well. Using just a map, I drove way out to the other side of Lake County to a small house that looked like a shack. I had the best map you could buy and it still didn’t have all the streets on it, but I was good at finding places. It seemed to me that I was always building pools way out in the boonies. And it was always the last house on the right. As you can imagine, this place was way out in the middle of nothing.

When I arrived, I was still unaware that they had no electricity and started asking the standard questions of where did they want the pool and where did they want the pump and filter. “Pump and filter?” my salt-of-the-earth customer asked. He didn’t know what I was talking about as he just went to Rec Warehouse in Orlando and bought a swimming pool. He had no idea that a pool has to have a pump and filter. After I explained it to him, he of course wanted me to install the pool anyway and said that he would just have to figure it out later. It was only a 15’ round pool so we built it pretty quickly complete with its pump and filter pack and the pump’s cord that had nothing to plug into and we were soon on our way back to Orlando. In the eighties, electricity only came from overhead power lines and during the drive back I noticed that there were no lines going to some of the other houses and realized that my customer wasn’t the only one without electricity. Sounds crazy, huh?

For a few years after that and whenever I was way out in the boonies, I would pay attention to power lines and how they wouldn’t always reach all the homes. It’s almost unbelievable to think that there were homes as recent as the eighties in Florida that had no electricity. If I hadn’t seen it for myself, I wouldn’t believe it. Now of course electricity is everywhere. And if you are going to get a pool, you’ll need electricity. Here’s an idea of what you’ll need.

Whatever It Takes

Above ground swimming pools come with above ground pool pumps. I say this because pumps for in-ground pools are a little different. The two big differences are above ground pumps cannot draw water upward and that above ground pumps come only in 120V (volt) as they are not what is called “dual voltage”. Since pumps for above grounds only come as 120V, they all have standard three-prong plug cords attached to them. So due to these pumps having standard cords on them, the easiest way to get power to your pool is to use an extension cord connected to some outlet from the house.gfci break

I recommend only using an extension cord temporarily until you can have a permanent power line buried that runs to the pump. Many only use an extension cord as theymay not have the money to do it right. If this is the case for you, then use an extension cord that has at least a #12 gauge wire. You really want a #10 gauge, but these cords are pricey. You want a thicker extension cord, because a pool pump requires a good amount of electricity to run. So, if the wire in the extension cord is too thin then the cord can eventually burn up or overheat causing the pump not to run. Also, because the pump uses a lot of power, the outlet that you plug the extension cord into should be on what is called a “dedicated circuit”.  What’s that? A dedicated circuit or line or outlet is one that only goes to one place/outlet from the electric box. This means the outlet isn’t connected to other outlets or things that might use some of the electricity coming from the power source (box). Your pool pump is greedy. It’s going to want to have all the power available in the wire. If it shares the electricity with something else, it may cause the breaker to throw off. At that point, nothing will work until you turn the breaker back on in the electric box and that’s scary. Well, not too scary.

The Right Way to Power Your Pool Pump

So let’s say you can afford to get the proper power line run to the pool’s pump. What now? Well, if you are having an electrician do the job then he’ll figure out what he needs and may ask you to give him the requirements for the pool’s pump motor. He’ll then come out and see where your electric box is at your house and where the pump is and then depending on how much digging he has to do, will charge you accordingly. He’ll take it from there and all you’ll have to do is pay him and you’re done.

Doing It Yourself?

Here’s a list of what you need to know:

  1. At least a basic knowledge of electrical work
    I don’t need to tell you that electricity is scary and dangerous. If you don’t know enough about it, then satisfy your DIY urges elsewhere. Work some overtime and pay someone to do this.

    above ground pool pump motor label
    Find Your Motors Amps on the Label
  1. Find out how many amps the pool pump needs
    Amperage is the amount of electricity that runs through the electric wires. You need to know this for two reasons. One is so you can know what size breaker is needed at the electric box and the other so you know what size of wire to run to the pool’s pump. A typical above ground pool pump will require a 20-amp breaker and use #12 gauge wire to deliver the electricity.
  1. Does your swimming pool have any other electrical needs?
    Your swimming pool equipment may have other needs for electricity. Add-ons like ozonators, ionizers, and salt chlorine generators require electricity. These add-ons usually don’t use much electricity so you won’t have to upgrade the breaker and wire size needed for the pump. If these add-ons are made for above grounds then they usually have standard three-prong plugs so you want to make sure there is an outlet for them. Above ground pool lights will also need an outlet.breaker box wire gauges
  1. Follow the NEC codes
    I’m not one who always follows the rules, but when it comes to electricity it’s a really good idea. NEC is the acronym for National Electric Code and it can be found online or by calling your local building department or talking to an electrician. The NEC will tell you things like how far down to bury the wires, the wire size, breaker size, which weatherproof outlet to use, and grounding requirements.
  1. Consider getting a timer
    You’ll thank me later. Most above ground pool packages don’t come with pump timers. If you don’t have a timer, you or someone you consider responsible will have to turn the pool pump on and off every day as the pump needs to run daily. A timer will do this automatically. Believe me, getting a timer is worth the extra money and hassle.

The electrical component of an above ground swimming pool is pretty important. If you have a budget, don’t cut your corners here. If you have to, don’t buy that fancy float that holds four beers so that you can get your electrical work done right.

If you have any questions on your above ground pool services then we would be happy to help, feel free to give us a call at 1-877-372-6038 or email us at upload@inyopools.com If you liked this article then make sure to sign up for Blog and get our Free 128 Page Pool Care Guide.

author avatar
Dan Dougher

Related Videos

88 responses to “What are the Electricity Requirements for Above Ground Pools?”

  1. Andy Avatar

    One thing which is essential for any outdoor installation or where there is water is an earth leakage breaker. Over in the UK we call them RCD (Residual Current Device) and I recommend a 30mA unit.

    They work by comparing the live and neutral currents in the cable and immediately disconnect the power if they are not the same. This will prevent you being killed by electrocution as a result of a fault in the pump or other pool wiring because some current will flow to earth through the equipment or yourself resulting in an imbalance in Live and Neutral. The RCD will detect this and immediately switch off the power before you are injured. Note that a RCD will not protect you if you shove your fingers into both the live and neutral power connections but it will protect you from most other conditions.

    If you are using a generator then you should use a ground rod to ensure that the system is properly earthed and to enable the RCD to detect faults.

    1. Dan Dougher Avatar

      I don’t know that I’d call it essential as I have done outdoor installations for three decades and have never seen or heard what you are talking about. Maybe the UK has man-made electric current running through the ground water, But not here in the US. Our building codes are pretty good though. Some of the best in the world, I’d say.

      1. jakeease Avatar

        I’d never heard of an RCD either–Google and Wikipedia say it’s another name for GFCI.

  2. rick Avatar

    My AGP is about 4′ from the back wall of my house right outside of the basement. The panel is about 30′ away towards the front of the house. My question is, is it ok to run my wire through the joists and through the back wall to an outlet i’ll install on the back wall?

    1. Dan Dougher Avatar

      Yes. there are electrical wires running through most attics.

  3.  Avatar

    I have a filter pump and a saltwater system both with gfi cords but only have one outdoor outlet. Both want fit in same outlet. Can I use extension cord for one? And is it safe to have both in same outlet

    1. Dan Dougher Avatar

      If the outlet is on a “dedicated circuit” then you can use it for both. You may be able to use it for both regardless as the chlorine generator typically doesn’t use much electric. And it is safe as long as the outlet has a Gfci (or Gfi as some call it). I’m not sure on cords with them built-in though.

  4. Scott webb Avatar

    How do I ground pool or does it have to be

    1. Matthew Simmons Avatar

      Yes, if you want safe pool equipment, ground or use a bonding wire. Step 10 on this guide explains how to bond a pump motor: How To Wire A Pool Pump

      1.  Avatar

        If the breaker is 20 amp does the gfci need to be 15 or 20 amp?

        1. Matthew Simmons Avatar

          Breakers have a GFCI built-in, at least most that I have seen. But if you have a separate GFCI, get one that matches your breaker amp rating.

      2. Tammy Avatar

        Do you have to plug the pool pump into a gfi plug

  5. ernesto Avatar

    I’m running underground wire to my pool pump which is a 2hp. will the 12/2 type uf-b wire be good? pump is roughly about 60 feet from the panel

    1. Bill Trueworthy Avatar

      Speak to your township official. direct burial depth is often different from conduit depth. Also, Most require thhn thwn wire. Many towns require a separate GFCI service outlet too and pool location distance from boundaries needs to be adhered to. Also, YOUR fence must surround the yard or pool (if you share a neighbors fence along a side, that doesnt cut it with most towns) and conduit proximity to pool necessitate a call to the town. Your 2HP circuit would be 220Vac so the 12 gauge would work… However, if you have future plans in the area like lighting maybe consider putting in a outdoor subpanel. Its all very easy for a diy-er and you’ll save a lot of money,,,if you are nervous, find a friend with electrical understanding for that part. Definitely ask for a consult with your towns electrical inspector because electricity (natural and home powered) is serious stuff when people are in a pool

  6.  Avatar

    Thank you sir for your wealth of information!

  7.  Avatar

    Matthew, you replied to my post on August 10,but your pump motor wire gauge guide does not display? Can you format differently or provide a link please? This was my original post. My pool pump will be located approximately 175 from service panel. Will a 1 hp pump be sufficient with a 20 amp circuit and 12 g wire for a 28ft pool.

    Thank you!

    1. Matthew Simmons Avatar

      Sorry about that. Here you go:

      pump motor wire gauge guide

      1.  Avatar

        Still having trouble, link is not working

    2. Johnny Avatar

      Did you every get a response, because the image he’s sending is not showing up in this thread.

  8.  Avatar

    Could a generator be used instead of an extension cord?

    1. Matthew Simmons Avatar

      A generator could be used in place of an extension cord, but the engine sound and gas fumes could dampen pool fun for swimmers.

      1. Desiree Avatar

        Can I use a Honda generator to run the over ground pool pump and if so is a 2000 ok ?

        1. Matthew Simmons Avatar

          As long as the generator’s watt output is great than the pump’s need, then it should be fine.

        2. b potteiger Avatar

          ifyou use a generator it must be grounded to your house plumbing or a 10 ft grounding rod drove on the ground about 9 feet

          1. Dan Dougher Avatar

            I’m not at all sure what you mean. Why do think you need a ground rod? Need more info. Sorry.

          2. Christian Avatar

            Pls I have a contract to do electrical piping for swimming pool and this my first time to do this work. Pls I need help. Thanks

      2. BobMac Avatar

        Dampen pool fun for swimmers? You are so punny! 😉

  9.  Avatar

    My pool pump will be located approximately 175 from service panel. Will a 1 hp pump be sufficient with a 20 amp circuit and 12 g wire for a 28ft pool.

  10. Larry Avatar

    Thank you for the info…Question: Would a 3/4 horse pump at 45 feet need a 12 gauge wire?

    1. Matthew Simmons Avatar

      If you are running the motor on 115 volts, 12-gauge would work fine.

      1. Maggi Avatar

        Can a 14 gauge work?? On a game sand pro 3/4 hp pump

        1. Matthew Simmons Avatar

          What is the amp usage on the motor label? Also, what is the distance between the light source and the pump?

        2. Dan Dougher Avatar

          14 gauge extension cord? Probably not.

      2. Tab Avatar

        I am wondering I have a electrical line in my back yard they put it 4ft below ground level inside of conduit and grounded can I put a above ground pool over it and access points on either end is at least 15ft from where pool is going to be located

        1. Matthew Simmons Avatar

          My first guess would be, no you can’t. But you probably want to check local codes to determine if that is allowable in your area.

          1. J. Orman Avatar

            Ok, got IN ground pool, 2hp motor, 98ft from breaker box. Is 12/2 on a 20 or 25 amp breaker work?

          2. Matthew Simmons Avatar

            What voltage are you using, 115 or 230?

            pool pump motor wire gauges

        2.  Avatar

          What type of outlet do I need

          1. Matthew Simmons Avatar

            Above ground pool pumps are usually wired with a 3-prong or a twist-lock cable. WHichever you use is determined by your preference or whatever you have onsite.

      3.  Avatar

        Can I put an above ground pool by the electric meter that’s on the house

        1. Matthew Simmons Avatar

          What kind of distance are you talking about?

          1. Joseph Avatar

            How long is the extension cord coming off the pool