Since the cells are of the same length, no replumbing is required. The new cell will connect to the existing unions. No problem.

As far as compatibility, there are some limitations for older AquaRite systems. T-cell 15 will work with all revisions of the AquaRite. However, the T-cell 3, 5, and 9 will only work with revisions 1.5 and higher. You can check their revision by pushing the diagnostic button seven times.

If you decide to change the T-cell, make sure you change the cell type that’s displayed in the control box. Otherwise, the system will receive incorrect salt readings, and it won’t produce chlorine.

To change the cell type in the control box, set the main toggle switch to “auto”. Then press the diagnostic button until the “T” number appears. Slide the toggle switch to “super chlorinate”, and then back to “auto”. The cell type will change. Repeat this process until the cell type in the display matches the new cell type.

If you have any questions, please leave them down below. If you like these videos, please select “like”, and subscribe to Inyo’s YouTube channel. Thank you for joining us.

author avatar
Matthew Simmons Technical Writer & Pool Product Expert
Swimming pool expert at InyoPools and host of Poolside Chat, brings over a decade of experience in the pool industry.

Related Videos

52 responses to “PSC Ep. 71: Are T-Cells interchangeable on Hayward AquaRite Systems?”

  1. Melissa Avatar

    I currently have a Tcell-15 -LS-CUL can I use a Tcell – 925. I have a Hayward pro logic system. I am assuming that I will now need more salt now? I used to need 1800PPM and now looks as though I need more to run the cell. Is this correct?

    1. Leon Avatar

      Always test salt levels before adding salt. It’s easier to add more after confirming salt levels thank it is to drain and fill after adding too much. An aging cell will start to read lower than actual salt level.

    2. Frank Avatar

      I purchased a second hand Aquarite 1.4 chlorine generator, is cell T-15 the only one compatible?

      1. Matthew Simmons Avatar

        Yes, the TCELL15 is the only cell option for a 1.4 firmware control unit. To use one of the other turbo cell options, you’d need to replace the control’s GLX-PCB-RITE